skip to Main Content

Collision resilient shield 1370mm wide with accessory rail

  • 0590-1060-05
    Collision resilient shield 1370mm wide with 570mm accessory rail

Want a quote for this product?

Either register online, or talk to us now. See below.

Description

Table Mounted Shield With Integrated Accessory Rail & Patented Collision Tolerant Pivotal Arm.
(Complete With 10 MM Thick 570 MM Long Integrated Accessory Rail)

This Lower Body Shield Substantially Reduces Exposure To Scatter Radiation Emanating From The Table Or Patient’s Body. The Shield Comprises A Lightweight And Durable Structure, With Enhanced Friction Maintaining Middle Link And Pivotal Arm Supporting A Flexible Lead Curtain. A Unique Patented Mechanism Enables The Pivotal Arm To Move Up When In Collision With C-Arm Equipment. Semi-Flexible Tops Shield Can Be Added To Provide Greater Protection To The Upper Body, Which Can Be Quickly Removed To Ease Patient Transfer And Access.

The Shield Easily Mounts To Either Side Of The Table Allowing The Pivotal Arm To Always Face The Head End.
A 720 MM Wide Attachment Bracket Slides Onto A 25 MM High Tableside Accessory Rail (Maximum 11MM Thick).  The Securing Handle Position Allows The Shield To Overhang The Rail End And Be Repositioned Further Along The Table If Required.

Flexible X-Ray Protective Curtains

  • The Curtains Form A Large (1350 MM Wide X 700 M High) Safe Zone Of Occupancy For The Radiologist (Or Cardiologist) And Another Person Standing Near By.
  • The Curtains Form Around An Under Table X-Ray Tube Without Impeding Movement.
  • The Curtain’s Inner 0.5 MM Lead Equivalent Layer Is Bonded To Its Outer Covering.  
  • The Pivotal Arm And Middle Link Can Swivel Outwards From The Table Side To Form A 480 MM Or 650 MM Wing, Or Inwards To Conform To The Shape Of The Table.

Optional Top Shields

  • Optional Detachable Tops Shields Overlap One Another To Provide Additional Protection To The Upper Body.
  • These Semi-Flexible Tops Stand Above The Table And Can Be Moved Towards The Patient As Required.
  • Each Can Be Quickly Removed To Aid Patient Access.
  • A 570 MM Wide Top (0590-1075-05) Attaches To The Pivotal Arm, Accompanied By A 270 MM Wide Top (0590-1080-05) On The Middle Link And An Adjacent, Shorter 270 MM Wide Top (0590-10850-05) On The Attachment Bracket.
  • The X-Ray Attenuating Material Used In All Tops Has A Lead Equivalent Of 0.5MM.

Get a Quote Easy As

1. Register / Login   2. Select your products   3. Click to get a quote

OR TALK TO US NOW - Freephone 0800 32 40 32 or email [email protected]